The two-colour method is based on optical pyrometry and can readily be implemented at a modest cost for the measurement of the instantaneous flame temperature and soot concentration in the cylinders of diesel engines. With appropriate modification, this method can be applied to other continuous and intermittent combustion systems, such as those for gas turbine and boiler burners. This paper outlines the theoretical basis of the method, with particular attention being paid to the assumptions relating to the evaluation of the flame temperature and soot concentration. A companion paper deals with the practical problems involved in constructing a working system, including suitable calibration techniques, and assessment of the method accuracy.